AV-LZ SERIES
FLEXIBLE MICROSTRIP
TRANSMISSION LINES
FOR LASER DIODE DRIVERS
In many high-current laser diode testing applications, it is 
(approximately  1  cm  × line width) with accessible output 
not possible to use a 50 Ohm termination - typically the 
and ground solder pad areas. The ground conductor and 
load   is   closer   to   1   to   12  Ohms.   For   these   applications, 
signal conductor on the other end of the line are exposed 
Avtech   offers   the   unique   AV-LZ   and   AV-CLZ   series   of 
for convenient solder connection. Scissors or a sharp knife 
transmission lines that have characteristic impedances (Z0) 
may be used to cut the line to shorter lengths as required. 
in   this   range.   When   a   transmission   line   with   a 
The input end of the line can be left unterminated (i.e., the 
characteristic   impedance   of   Z0  is   used   to   drive   a   load 
line is snipped with scissors, and the film is peeled back 
impedance of RL, and Z0  = RL, ideal matching will occur. 
slightly   to   provide   soldering   access   to   the   copper   foils). 
Under these conditions, longer-than-normal cable lengths 
Alternatively, the input end can be supplied terminated with 
can be used without introducing significant ringing, speed 
a male DB-37 connector, suitable for mating to a variety of 
degradation, or other distortions.
Avtech pulsers (check the pulser datasheet to confirm that 
The   newer   AV-CLZ   transmission   lines   are   described   in 
it has a DB-37 female output connector.) Pins 1-19 of each 
detail at  http://www.domain.avtechpulse.com/transmission. 
connector are connected to the signal line, and pins 20-37 
These   highly-rugged   lines   are   recommended   for   most 
are connected to the ground line.
applications. However, for applications requiring a lighter, 
Avtech can provide other connector arrangements, suitable 
more flexible cable, the older AV-LZ series is still available.
for   use   with   older   equipment   and   other   instruments. 
AV-LZ transmission lines consist of a sandwich structure of 
Contact   the   factory   (info@avtechpulse.com)   with   your 
three   layers   of   polyimide   Kapton   film   and   two   layers   of 
special requirement.
copper   foil,   which   results   in   a   highly   flexible   flat 
The   AV-LZ   is   suitable   for   laboratory   use,   but   is   not 
transmission line with low characteristic impedance. 
recommended for production test environments due to its 
Connection   to  the  output   end  of   the   line   is   normally  via 
relatively fragile nature compared to the more rugged AV-
soldering, and the lines are normally supplied with one end 
CLZ series.
soldered to a smal  piece of 1/16" glass epoxy circuit board 
Model:
AV-LZ1
AV-LZ2
AV-LZ3
AV-LZ6
AV-LZ10
AV-LZ12
Characteristic impedance (Z0, ±20%):
1 Ω
2 Ω
3 Ω
6 Ω
10 Ω
12 Ω
Maximum pulse current:
100 A
50 A
30 A
15 A
10 A
8A
Series resistance:
(signal and ground lines)
0.05 Ω / m
0.1 Ω / m
0.15 Ω / m
0.3 Ω / m
0.5 Ω / m
0.6 Ω / m
Rise time:
< 5 ns
Maximum width:
25.4 mm (1”)
13 mm (0.52”)
Output end termination:
25.4 × 10 mm circuit board, 
13 × 10 mm circuit board, 
suitable for soldering
suitable for soldering
Input end termination:
Standard: none.   Optional1: DB-37 male. Pins 1-19 = signal, pins 20-37 = ground.
Length:
1 meter standard, 2 meters optional2
Temperature range:
+5°C to +40°C3
Bend radius:
1 cm
1) Add the suffix -DB37M to specify the male DB-37 input termination.
nitrogen temperatures, but Avtech does not recommend the LZ series for 
2) Add the suffix -2M to specify 2 meter length.
use at these temperatures. Damage at low temperatures is not covered by 
3) Some users have reported successful use of the LZ series at liquid 
the warranty. Usage at cryogenic temperatures is "at your own risk".
LZ CABLE
OUT
GROUND
PAD
PAD
Layout of output end termination
Photo of output end termination
printed circuit board
printed circuit board
See http://www.avtechpulse.com/appnote/techbrief10 for AV-LZ application information!